How to calculate a PCR master mix
A master mix combines everything shared between your PCR reactions in one tube, so each reaction gets identical amounts and you pipette far fewer small volumes. The calculation has two parts: volumes per reaction, then scaling up.
Step 1: Volume of each component per reaction
For every component with a stock and final concentration:
volume per reaction = final concentration ÷ stock concentration × reaction volume
A typical 25 µL reaction:
| Component | Stock | Final | µL / reaction |
|---|---|---|---|
| Reaction buffer | 10X | 1X | 2.5 |
| dNTP mix | 10 mM each | 0.2 mM each | 0.5 |
| Forward primer | 10 µM | 0.5 µM | 1.25 |
| Reverse primer | 10 µM | 0.5 µM | 1.25 |
| DNA polymerase | per manufacturer | 0.25 | |
| Template DNA | added to each tube | 1 | |
| Water | to 25 µL | 18.25 | |
Step 2: Scale up with extra volume
Liquid is lost on tip walls, so make mix for a few more reactions than you need. With 10% extra, 12 reactions become 13.2. Multiply every component except the template by 13.2:
- Buffer 33 µL, dNTPs 6.6 µL, each primer 16.5 µL, polymerase 3.3 µL, water 240.9 µL
- Master mix total: 316.8 µL. Dispense 24 µL into each tube, then add 1 µL template.
Good practice
- Add water first and polymerase last, and keep the mix on ice.
- Mix by gentle pipetting or flicking, then spin down. Don't vortex enzyme-containing mixes hard.
- Always include a no-template control (water instead of template) to catch contamination.
- Check whether your buffer already contains MgCl₂ (often 1.5 mM). If you add extra Mg²⁺, include it as its own line.
Frequently asked questions
How much extra master mix should I make?
About 10% is typical, or one extra reaction per ten. Use more for many reactions, viscous mixes or multichannel pipetting.
Why does my water volume come out negative?
The components add up to more than the reaction volume. Use more concentrated stocks, lower final concentrations, or increase the reaction volume.
Should the template go in the master mix?
Only if every reaction uses the same template. Usually templates differ, so they are added to each tube separately.